Aluminum Wiring in
Residential Properties
This page contains information for consumers and building professionals regarding aluminum
electrical wiring in residential properties. The contents are the result of study of this
topic and represent the opinion of the author. Links to actual documents are included on
this page.
The Hazard
Aluminum wiring, used in some homes from the mid 1960's to the early 1970's, is a
potential fire hazard. According to the U.S. Consumer Product Safety Commission, fires and
even deaths have been reported to have been caused by this hazard. Problems due to
expansion can cause overheating at connections between the wire and devices (switches and
outlets) or at splices. CPSC research shows that homes wired with aluminum wire
manufactured before 1972 are 55 times more likely to have one or more connections reach
"Fire Hazard Conditions" than are homes wired with copper. Aluminum wiring is
still permitted and used for certain applications, including residential service entrance
wiring and single-purpose higher amperage circuits such as 240V air conditioning or
electric range circuits.
Reducing Risk
As of the current date of this page only two remedies have been recommended by the CPSC:
discontinued use of the aluminum circuit or, less costly, the addition of copper
connecting "pigtail" wires between the aluminum wire and the wired device
(receptacle, switch, or other device). The pigtail connection must be made using only a
special connector and special crimping tool licensed by the AMP Corporation.